Gas control valve – L.B. White Oval 80™ Radiant User Manual

Page 21

Advertising
background image

21

1. Disconnect the gas hose and remove the sediment

trap from the burner box.

2. Remove the igniter. See IGNITER servicing.

3. Remove the four 3/8 in. nuts from the burner

mounting studs. See BURNER ORIFICE servicing.

4. Remove the burner orifice and the burner inlet plate.

See Fig. 28.

FIG. 28

5. Remove the four gas control valve mounting screws.

See Fig. 29.

FIG. 29

6. Remove the gas valve with manifold from the burner

box.

FIG. 30

If the grommet is dislodged from the center partition

hole, the grommet must be installed within the

hole at reassembly.

Position the grommet into the partion hole prior to

installing the valve and manifold assembly.

-- The center partion panel hole rides within the

grommet’s groove.

To allow easier installation of the manifold, evenly

apply a small amount of liquid dish soap to the inner

diameter of the grommet. See Fig.31.

Hold the grommet in position from the burner side

of the partition panel while pushing the manifold

through the grommet’s hole.

FIG. 31

GAS CONTROL VALVE

ORIFICE

BURNER INLET PLATE

MOUNTING
SCREWS

PARTITION HOLE

GROMMET

APPLY HERE

Advertising