Electrical installation − ems version – Lenze 8400 protec Manual User Manual
Page 123
Electrical installation − EMS version
Devices in a power range of 0.75 ... 4 kW (3/PE AC 400 V)
Terminal assignment of the power connections
l
123
EDS84DPS424 EN 5.0
X11 − port for mains loop−through technique (optional)
Pin
Connection
Description
Data
DESINA type Q4/2, sockets
Version: 8400 protec EMS
Type designation:
l
E84DEM... (half wave)
l
E84DLM... (half wave coded)
l
E84DPM... (power wave)
l
E84DDM... (DECA bus)
84DWTX0110
1
L1
Mains phase L1
Max. 6 mm
2
2
L2
Mains phase L2
3
L3
Mains phase L3
4
n. c.
Not assigned
+
PE
PE conductor
11
n. c.
Not assigned
Max. 2.5 mm
2
12
n. c.
Not assigned
X11 − port for loop−through technique DC supply (optional)
Pin
Connection
Description
Data
DESINA type Q4/2, sockets
Version: 8400 protec EMS
Type designation:
l
E84DFM... (inductive)
84DWTX0110
1
n. c.
Not assigned
Max. 6 mm
2
2
+UG
DC−bus voltage +
3
−UG
DC−bus voltage −
4
n. c.
Not assigned
+
PE
PE conductor
11
+
External supply voltage for motor
holding brake 24 V DC
Max. 2.5 mm
2
12
−
External reference potential 24 V DC