Electrical installation − ems version – Lenze 8400 protec Manual User Manual

Page 123

Advertising
background image

Electrical installation − EMS version

Devices in a power range of 0.75 ... 4 kW (3/PE AC 400 V)

Terminal assignment of the power connections

7

l

123

EDS84DPS424 EN 5.0

X11 − port for mains loop−through technique (optional)

Pin

Connection

Description

Data

DESINA type Q4/2, sockets

Version: 8400 protec EMS
Type designation:

l

E84DEM... (half wave)

l

E84DLM... (half wave coded)

l

E84DPM... (power wave)

l

E84DDM... (DECA bus)

84DWTX0110

1

L1

Mains phase L1

Max. 6 mm

2

2

L2

Mains phase L2

3

L3

Mains phase L3

4

n. c.

Not assigned

+

PE

PE conductor

11

n. c.

Not assigned

Max. 2.5 mm

2

12

n. c.

Not assigned

X11 − port for loop−through technique DC supply (optional)

Pin

Connection

Description

Data

DESINA type Q4/2, sockets

Version: 8400 protec EMS
Type designation:

l

E84DFM... (inductive)

84DWTX0110

1

n. c.

Not assigned

Max. 6 mm

2

2

+UG

DC−bus voltage +

3

−UG

DC−bus voltage −

4

n. c.

Not assigned

+

PE

PE conductor

11

+

External supply voltage for motor
holding brake 24 V DC

Max. 2.5 mm

2

12

External reference potential 24 V DC

Advertising