Technical data – Lenze 8400 protec Manual User Manual

Page 45

Advertising
background image

Technical data

General data and operating conditions

4

l

45

EDS84DPS424 EN 5.0

EMS version

Half−wave system

E84DE..., E84DL...

Control bar

Z system

No

Number

2

Signal level

Full wave

Positive half wave

Negative half wave

Coded half wave

Reference voltage or switched
voltage

L3
L1 possible with different hardware configuration

Rated voltage

400−480 V AC, 50−60 Hz

Coded half wave: 230 V AC, 50−60 Hz

Switching threshold

50 Hz: 270 V AC (243 ... 297 V AC)
60 Hz: 330 V AC (297 ... 363 V AC)

Power input

1.5 W (400 V AC)

for 1 x half wave

Signalling bar

Number

1

Signal level

Full wave

Positive half wave

Negative half wave

Reference voltage or switched
voltage

L3
L1 possible with different hardware configuration

Short circuit protection

PTC protection (500

W connected in series)

Reference voltage

400 ... 480 V

Switching current

max. 28 mA AC

Advertising