Technical data – Lenze 8400 protec Manual User Manual
Page 45
Technical data
General data and operating conditions
l
45
EDS84DPS424 EN 5.0
EMS version
Half−wave system
E84DE..., E84DL...
Control bar
Z system
No
Number
2
Signal level
Full wave
Positive half wave
Negative half wave
Coded half wave
Reference voltage or switched
voltage
L3
L1 possible with different hardware configuration
Rated voltage
400−480 V AC, 50−60 Hz
Coded half wave: 230 V AC, 50−60 Hz
Switching threshold
50 Hz: 270 V AC (243 ... 297 V AC)
60 Hz: 330 V AC (297 ... 363 V AC)
Power input
1.5 W (400 V AC)
for 1 x half wave
Signalling bar
Number
1
Signal level
Full wave
Positive half wave
Negative half wave
Reference voltage or switched
voltage
L3
L1 possible with different hardware configuration
Short circuit protection
PTC protection (500
W connected in series)
Reference voltage
400 ... 480 V
Switching current
max. 28 mA AC