Braking operation

Braking operation with external brake resistor

Wiring of brake resistor

9

l

155

EDS84DPS424 EN 5.0

Evaluation of the thermal contact via digital input

As an alternative to the integration of the thermal contact via a mains contactor, the brake
resistor can also be monitored via a digital input. Please use a Lenze system cable. The
response to the input signal must be parameterised in the FB Editor using the »Engineer«.

DI1

X41

GND-IO

GIO

24O

3

.3k

3

.3k

DI2

RB2

RB2

RB1

RB1

T1

T2

ERB...

X20

E84D...

8400DDI032

E84D...

8400 protec

X41

Digital input

X20

Brake resistor connection

ERB...

Brake resistor

Evaluation of the thermal contact via analog input

As an alternative to the integration of the thermal contact via a mains contactor, the brake
resistor can also be monitored via an analog input. Please use a Lenze system cable. The
response to the input signal must be parameterised in the FB Editor using the »Engineer«.

GND-A

X50

24O

E84D...

GA

RB2

RB2

AI

RB1

RB1

AU

T1

AR

T2

+10 V /

10 mA

ERB...

X20

8400DAI031

E84D...

8400 protec

X50

Analog input

X20

Brake resistor connection

ERB...

Brake resistor

,

Further information on brake resistor monitoring is provided in:

ƒ

the 8400 protec software manual, chapter "Motor control"

è

"Monitorings"