ClearCube R Series Pentium 4 User Manual

Page 133

Advertising
background image

ClearCube Product Manual and Installation Guide

Appendix C – Technical Support • 123

packaged with power cords rated at 10 amps. Older model BackPacks utilized 10

amp-rated power cords that are NOT approved for use with current model BackPacks

on 110–130-volt power systems. The standard 10 amp power cords are acceptable

for use with the Fiber Transceiver. Refer to the Safety Guidelines on page 4 for more

information.

The maximum steady-state current draw of a single fully loaded Cage ranges between

6 and 8 amps at 120 VAC, based on the level of user activity. The peak initial current

draw is 12 amps. (See Table 3 Power and Cooling Requirements – R1200 on page 36

for more information.) If you are placing multiple Cages on a single power circuit,

make sure that the circuit can safely handle the combined currents of all the

equipment. Therefore, if you place two Cages on a single branch circuit, it must be

able to support a peak current of 25 amps at 120 VAC.

Advertising