Changing the ip address of the rmc – ClearCube R Series Pentium 4 User Manual

Page 78

Advertising
background image

68 • Cage and Blade Installation

ClearCube Product Manual and Installation Guide

NOTE: Every primary Cage/BackPack with an RMC installed is shipped with the same

default network settings. If you are using multiple Cage groups, you must

configure new IP addresses per the instructions below to avoid a conflict.

Default RMC Settings:

IP Address:

192.168.1.251

Gateway:

192.168.1.1

Network:

192.168.1.0

Netmask:

255.255.255.0

Changing the IP Address of the RMC

To change the IP address on an RMC, do the following:

1. From any computer on the network connected to the RMC, open a telnet session to log

into the RMC using the default RMC IP address of 192.168.1.251. If your network

settings are incompatible with the RMC’s default settings, then you need to select one

computer (notebook, Blade, or other PC) that you can use to program the RMC. Set

this computer’s network settings to be compatible with the RMC default settings and

connect its network port directly to the CONTROL IN port on the Cage using the

provided cross-over cable. To telnet into the RMC from a DOS prompt, type:

H:\>Telnet 192.168.1.251

The result should be:

Password:

2. Type

clearcube

as the default password. For example:

Password: clearcube

NOTE: You will not see any letters as you type the password. The result should

be:

RMC Configuration

1. IP address: 192.168.1.251

2. Gateway: 192.168.1.1

3. Network: 192.168.1.0

4. Netmask: 255.255.255.0

5. Password: clearcube

6. Exit

3. From the list of options, select

1

to change the IP address. For example:

>1

The result should be:

>1

new ip:

4. Type in the desired new IP address. For example:

>1

new ip: 192.168.1.100 (your desired IP address)

The result should be:

RMC Configuration

Advertising
This manual is related to the following products: