FAA-27, Technical Manual, Rev. 1.1, June 2014

Page 11 of 21

5. Adjustments

5.1 Adjustment with Rotary Switches

To start the adjustment the programming switch should be at analog output type
position, V or I.
Z and G positions of the programming switch are used for performing zero and gain
adjustments in sequence. Analog output is changed by turning the adjustment switch
as described in the table below.

Adjustment rotary

switch position

Rotary switch description

Run

LED

Do not change, operation

On

Decrease ( - ) / Increase ( + ) in slow steps

Flash

Decrease ( - ) / Increase ( + ) in medium steps

Flash

Decrease ( - ) / Increase ( + ) in big steps

Flash


RUN LED flashes to indicate the instrument is not in operation.

Zero Adjustment

Connect the measurement instrument to the analog output.

Unload the scale.

Turn the programming switch to the Z position from the analog output type

position.

Increase or decrease the analog output by adjustment rotary switch.

Never bring the adjustment switch position to

position in this adjustment.

The adjustment switch must be at 0 - position at the end of the adjustment.

Turn the programming switch to analog output type position (V or I) to start the

operation or to the G position to start gain adjustment.

Gain Adjustment

Connect the measurement instrument to the analog output.

Load the scale.

The analog output value should be calculated for the applied load.