► For the CDM-Qx modem, the code is the decimal number indicating the problem
parameter within its MGC configuration code:
00
NO
ERROR
01 ITF Interface
02
LBO
T1 Line Build-Out
03
FRM
Framing mode
04
TFQ
Tx Frequency
05
TFT
Tx FEC Type
06
TMD
Tx Modulation
07
TCR
Tx FEC Code Rate
08
TDR
Tx Data Rate
09
TSI
Tx Spectrum Invert
10
TSC
Tx Scrambler state
11
TPL
Tx Power Level
12
TCK
Tx Clock
13
TDI
Tx Data Invert
14
TXO
Tx Carrier State
15
AUP
AUPC enable
16
APP
AUPC parameters
17
WUD
Warm-Up Delay
18
TXC
Tx common output state
19
TRS
Tx Reed-Solomon
20
TXA
Tx roll-off (alpha) factor
21
TCI
Tx Data Clock Invert
22
RFQ
Rx Frequency
23
RFT
Rx FEC Type
24
RMD
Rx Modulation
25
RCR
Rx FEC Code Rate
26
RDR
Rx Data Rate
27
RSI
Rx Spectrum Invert
28
RDS
Rx DeScrambler state
29
RDI
Rx Data Invert
30
RSW
Rx Sweep Width
31
EBA
Eb/No Alarm point
32
BCS
Rx Buffer clock source
33
RRS
Rx Reed-Solomon
34
RBS
Rx Buffer size/enable
35
RCI
Rx Data Clock Invert
36
ERF
External Reference setting
37
EFM
EDMAC Framing mode
38
ESA
EDMAC Slave Address range
39
TST
Test mode (read-only)
40
MSK
Alarm Masks
41
RTS
Request-To-Send control
42
SSI
Statistics Sample Interval
43
CNM
CnC Mode
44
CFO
CnC Frequency Offset
45
CSD
CnC Min/Max Search Delay
46
CRA
CnC Re-acquisition Time
SWITCH ALARM: MODEM COMMS
PROBLEM, POSITION 2
There is a fault. There is a problem with the I/O communications with Traffic Modem. The front
panel LED “Unit Status” will be RED.
Suggestions:
•
Check Cable Connections – refer to
Chapter 4. CABLES AND CONNECTIONS.
•
Check Modem Configurations – refer to
Chapter 5. MODEM, RMI/TMI, AND
SWITCH CONFIGURATION.
SWITCH ALARM: TMI:I/F
MISMATCH, POSITION 2
There is a fault. There is a mismatch of data interface type between what has been selected in the
modem menu and the TMI type that is connected to that Traffic Modem. The front panel LED
“Unit Status” will be RED.
Suggestion: Ensure the modem interface type is compatible with the TMI being used. The
CDM-600s have both TX and RX interface types. The CDM-570s just have one unit interface
type. Either edit the modem interface setting(s) or swap the TMI.