Mocomtech CRS-300 User Manual

Page 263

Advertising
background image

CRS-300 1:10 Redundancy Switch

Revision 16

Remote Control

MN/CRS300.IOM

C–13

Parameter Type

Command
(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Response to Command

(Target-to-Controller)

Query

(Code and

qualifier)

Response to query

(Target-to-Controller)

Serial Number

N/A

9 bytes, numerical Query only.

Unit returns its 9-digit serial number.
Example: SNO=176512523

N/A SNO?

SNO=xxxxxxxxx
(see Description of
Arguments)

Software
Revision

N/A

4 bytes, numerical Query only.

Unit returns the value of internal software revision installed
in the unit, in the form x.xx
Example: SWR=1.03 (Ver 1.03)

N/A SWR?

SWR=x.xx
(see Description of
Arguments)

Time

TIM=

6 bytes, numerical Command or Query.

The time from midnight, in the form hhmmss, where
hh = hours, between 00 and 23,
mm = minutes, between 00 and 59, and
ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and
59 seconds from midnight.

TIM= (message OK)
TIM? (received OK, but
invalid arguments)
TIM# (message OK, but
only permitted in Remote
mode)

TIM? TIM=hhmmss

(see Description of
Arguments)