Mocomtech CRS-300 User Manual

Page 262

Advertising
background image

CRS-300 1:10 Redundancy Switch

Revision 16

Remote Control

MN/CRS300.IOM

C–12

Parameter Type

Command
(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numerical codes,

that is, ASCII codes between 48 and 57)

Response to Command

(Target-to-Controller)

Query

(Code and

qualifier)

Response to query

(Target-to-Controller)

Switch Alarm
Mask

SAM=

1 byte, numerical

Command or Query.
Where x indicates the Switch alarm mask:
0 = no faults masked
1 = PSU-A faults masked
2 = PSU-B faults masked

SAM= (message OK)
SAM? (received OK, but
invalid arguments found)
SAM# (message OK, but
only permitted in Remote
mode)

SAM? SAM=x

(see Description of
Arguments)

SwitchDataTime

SDT=

1 byte, numerical

Command or Query.
This command allows the Switch to send commands to all
attached modems on a daily basis to set their time and
date values to the same as the Switch. This value is also
saved in nonvolatile memory to retain setting during a
power outage. The factory default setting is SDT=0.
SwitchDataTime, where x where:
0 turns off this feature.
1 enables this feature
Example: SDT=1

SDT= (message OK)
SDT? (received OK, but
invalid arguments)
SDT* (message OK, but not
permitted in current mode)

SDT? SDT=xx

(see Description of
Arguments)

Switch Global
Configuration

SGC= 29

bytes,

numerical

Command or Query.
Global configuration of the Switch, in the form:
OaaaaaaaaaaBNNbbrrMSAssssssss, where:
O = Operating Mode – same as OPM (1 bytes)
a = Active Modems – same as ACT (10 bytes)
B = Bridge/Backup State – same as BBU (1 byte)
N = Selected TM Number - same as BBU (2 bytes)
b = Backup Holdoff Time – same as BKH (2 byte)
r = Restore Holdoff Time – same as RSH (2 byte)
M = Modem Alarm Mask – same as MAM (1 byte)
S = Switch Alarm Mask – same as SAM (1 byte)
A = Audio Alarm Mask – same as AAM (1 bytes)
P = Priority mode – same as PRI
s = 7 spare bytes

SGC= (message OK)
SGC? (received OK, but
invalid arguments found)
SGC# (message OK, but
only permitted in Remote
mode)

SGC? SGC=OaaaaaaaaaaBNN

bbrrMSAPsssssss
(see Description of
Arguments)

Switch ID

SID=

24 bytes, ASCII

Command or Query.
A user-defined Switch ID, which is a fixed length of 24
characters.
Valid characters include:
Space ( ) * + - , . / 0-9 and A-Z.

SID= (message OK)
SID? (received OK, but
invalid arguments found)
SID# (message OK, but
only permitted in Remote
mode)

SID? SID=xxxxxxxxxxxxxxxxx

xxxxxxx
(see Description of
Arguments)