Multi-Tech Systems MTS2SA-T User Manual
Page 117
Chapter 10
− Modem Mode AT Commands, S-Registers, and Result Codes
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
117
Command:
+PSS
Use Short Sequence
Description:
Causes a calling modem to force either a V.92 short or full startup sequence as
defined by the +PQC command on the next and subsequent connections.
Defined Values:
+PSS0
The modems decide whether or not to use the short startup
procedures. The short startup procedures can only be used if enabled
by the +PQC command. (Default.)
+PSS1
Reserved.
+PSS2
Forces the use of the full startup procedures on the next and
subsequent connections independent of the setting of the +PQC
command.
Result Codes:
OK 0 - 2 in V.92 Mode (+MS=V.92)
ERROR
Report Commands:
+PSS?
Reports Selected Values.
+PSS=?
Reporting
Supported
Range of Parameter Values
Command:
–QCPC
Force Full Startup Procedure on Next Connection
Description:
Causes the modem to use full startup procedures on the next connection attempt
regardless of the setting of the +PQC command. After this attempt, the modem will
select the startup procedure as defined by the +PQC command. If a shortened
startup procedure is enabled by the +PQC command, then the quick connect profile
will also be updated on the next connection attempt.
Result Code:
OK In V.92 Mode (+MS=V.92)
ERROR
Command:
–QCPS
Enable Quick Connect Profile Save
Description:
This command controls whether or not the modem will save the generated quick
connect profile.
Defined Values:
-QCPS0
Do not allow the quick connect profile to be saved.
-QCPS1
Allow the quick connect profile to be saved. (Default.)
Result Codes:
OK in V.92 Mode (+MS=V.92) and quick connect is enabled (+PSS = 0)
ERROR
Report Commands:
-QCPS?
Reports Selected Value(s).
-QCPS=?