Front Panel Operation
MN/CDM570L.IOM
6–42
6.14 MONIT
(Monitor)
Select Alarms, Rx-Params, Event-Log, Stats, AUPC or ODU using the
◄ ►
arrow keys, then press ENTER.
If the user selects Alarms, the following sub-menu is displayed:
6.14.1 (MONIT)
ALARMS
IMPORTANT NOTE: The CDM-570L uses a system of Fault Prioritization. In each
category of fault, only the highest priority fault is displayed. For instance, if the
demodulator is unlocked, it is irrelevant if there are other receive faults present. If the
demodulator then locks, but there is a fault of a lower priority present, this will then be
displayed. This also holds true for the faults reported via the remote control. This system
cuts down significantly on unwanted and irrelevant fault reporting. A comprehensive list
of faults is shown at the end of this section.
Select Unit, Receive, Transmit or ODU, using the
◄ ►
arrow keys, then press
ENTER. Depending on the choice , one of the following menus will be shown:
(MON, ALARMS) UNIT (Unit alarms)
The screen will indicate if there are any Unit Faults. If not, it will display ‘None’.
Pressing ENTER takes the user back to the previous menu.
(MON, ALARMS) RECEIVE (Receive Traffic Status)
The screen will indicate if there are any Receive Traffic Faults. If not, it will
display ‘None’. Pressing ENTER takes the user back to the previous menu.
MONITOR:Alarms Rx-Params
Event-Log Stats AUPC ODU
Live Alarms:Unit Receive
Transmit ODU (
◄ ►,ENTER)
Unit Fault: -12 Volt PSU
is Under-Voltage (ENT)
Rx Traffic: AGC Alarm -
Reduce Input level (ENT)