(MON, ALARMS) TRANSMIT (Transmit Traffic Status)

The screen will indicate if there are any Transmit Traffic Faults. If not, it will
display ‘None’. Pressing ENTER takes the user back to the previous menu.

(MON, ALARMS) ODU (Outdoor Unit alarms)


The screen will indicate if there are any ODU Alarms. If not, it will display
None’. Pressing ENTER takes the user back to the previous menu.

LISTING OF PRIORITIZED FAULTS:

Unit Faults:
1) Power supply fault, +5 volts
2) Power supply fault , +12 volts
3) Power supply fault, –5 volts
4) Power supply fault, +23 volts
5) Power supply fault, –12 volts
6) Tx synthesizer lock
7) Rx 1

st

LO synthesizer lock

8) Rx 2

nd

LO synthesizer lock

9) Reference PLL lock
10) IP Module fault
11) EEPROM checksum error

Tx Traffic status:
1) No clock from terrestrial interface
2) Tx FIFO slip
3) Loss of External Reference
4) AUPC upper limit reached
5) AIS detected on incoming data (from terrestrial direction)
6) Bipolar violation on G.703 interface

Rx Traffic status:
1) Demodulator unlocked
2) AGC Alarm - signal out of range
3) RS Frame sync alarm
4) EDMAC Frame sync alarm
5) Buffer Underflow
6) Buffer Overflow
7) Eb/No alarm
8) AIS detected on incoming data (from satellite direction)

Tx Traffic: No Tx Clock
from Terrestrial (ENT)

ODU Alarms: BUC Current
Over Limit (ENT)