to Establish a network connection to the DMP 128:

1.

Open a TCP socket to port 23 using the mixer IP address.

notE: If the local system administrators have not changed the value, the

factory-specified default, 192.168.254.254, is the correct value for this field.

2.

The DMP 128 responds with a copyright message including the date, the name of the
product, firmware version, part number, and the current date/time.

a.

If the DMP 128 is not password-protected, the device is ready to accept SIS
commands immediately after it sends the copyright message.

b.

If the DMP 128 is password-protected, a

password

prompt appears below the

copyright message. Proceed to step 3.

3.

If the device is password protected, enter the appropriate administrator or user
password.

a.

If the password is accepted, the device responds with

Login User

or

Login

Administrator

.

b.

If the password is not accepted, the

Password

prompt reappears.

connection timeouts

The Ethernet link times out after a designated period of time of no communications. By
default, this timeout value is set to 5 minutes but the value can be changed (see

Ethernet

data port

on page 137).

notE: Extron recommends leaving the default timeout at 5 minutes and periodically

issuing the Query (Q) command to keep the connection active. If there are long

idle periods, disconnect the socket and reopen the connection when another
command must be sent.

Verbose Mode

Telnet connections can be used to monitor for changes that occur, such as SIS
commands from other Telnet sockets or a serial port. For a Telnet session to receive
change notices, the Telnet session must be in verbose mode 1 or 3 (see the

verbose

mode

SIS command on page 136). In verbose mode 1 or 3, the Telnet socket reports

changes in messages that resemble SIS command responses.

DMP 128 • SIS Programming and Control