Advanced aec controls – Extron Electronics DMP 128 User Guide User Manual

Page 49

Advertising
background image

advanced aEc controls

Click on the open/collapse icon at the bottom of the AEC dialog to reveal the advanced
AEC controls.
Advanced control functionality is as follows:

non-linear Processing (nLP) controls

Enable NLP — this box is selected by default. NLP is

necessary for the removal of echo.

NLP Presets — click a button to load a set of values

to the three NLP parameters; Max NLP Reduction,
Attack Time, and Release Time.

Soft

Normal

Aggressive

The default parameters (shown at right) match the Normal

preset.

Max NLP Reduction – the maximum possible reduction in echo artifacts that can

be applied. The range is 0.0 to 80.0 dB in 0.1 dB increments.
Default is 50.0 dB.

Attack Time – the speed in which NLP is applied. The range is 0.0 to 100.0 msec

in 0.1 msec increments.
Default is 6.0 msec.

Release Time – the speed in which NLP is released. The range is 1.0 to

3000.0 msec in 0.1 msec increments.
Default is 150.0 msec.

additional controls

Double Talk Echo Reduction – sets the amount of echo reduction applied

during double-talk. The range is 0.0 to 20.0 dB in 0.1 dB increments.
Default is 15.0 dB.

Comfort Noise – sets a comfort noise level in dB to eliminate states of complete

silence, which could be perceived as a failed connection. The range is 0.0 to 40.0 dB
in 0.1 dB increments.
Default is 0.0 dB which turns comfort noise off.

DMP 128 • Software Control

43