Advanced aec controls – Extron Electronics DMP 128 User Guide User Manual
Page 49
advanced aEc controls
Click on the open/collapse icon at the bottom of the AEC dialog to reveal the advanced
AEC controls.
Advanced control functionality is as follows:
non-linear Processing (nLP) controls
•
Enable NLP — this box is selected by default. NLP is
necessary for the removal of echo.
•
NLP Presets — click a button to load a set of values
to the three NLP parameters; Max NLP Reduction,
Attack Time, and Release Time.
•
Soft
•
Normal
•
Aggressive
The default parameters (shown at right) match the Normal
preset.
•
Max NLP Reduction – the maximum possible reduction in echo artifacts that can
be applied. The range is 0.0 to 80.0 dB in 0.1 dB increments.
Default is 50.0 dB.
•
Attack Time – the speed in which NLP is applied. The range is 0.0 to 100.0 msec
in 0.1 msec increments.
Default is 6.0 msec.
•
Release Time – the speed in which NLP is released. The range is 1.0 to
3000.0 msec in 0.1 msec increments.
Default is 150.0 msec.
additional controls
•
Double Talk Echo Reduction – sets the amount of echo reduction applied
during double-talk. The range is 0.0 to 20.0 dB in 0.1 dB increments.
Default is 15.0 dB.
•
Comfort Noise – sets a comfort noise level in dB to eliminate states of complete
silence, which could be perceived as a failed connection. The range is 0.0 to 40.0 dB
in 0.1 dB increments.
Default is 0.0 dB which turns comfort noise off.
DMP 128 • Software Control
43