Extron Electronics DMP 128 User Guide User Manual

Page 73

Advertising
background image

FBs Fixed Filters tab

Fixed filters are notch filters with an adjustable center frequency and Q, and up to 30 dB
of cut. The fixed filters are typically set by converting dynamic filters to fixed, however
adjustments to filter parameters can be manually made from the Fixed Filters tab.
Fixed Filters are inactive and the filter type is set to Unused by default (see rows 4 and 5

in figure 40).

Figure 40.

FBS Fixed Filters Tab

No filter parameters are displayed when the filter type is set to Unused. As a filter is

moved to the fixed filter tab from a dynamic filter, the filter becomes active and displays
Notch as the filter type. The parameters copied from the dynamic filter are displayed in

the same line. Once a fixed filter is active, settings can be modified or adjusted as needed.
Fixed filters can also be individually bypassed by clicking Bypass.
FBS Settings Ranges and Fixed Filter Defaults

FBS Parameter

Settings Range

Default Setting

Frequency

20 Hz to 20 kHz

N/A

Q

5.000 to 65.000

30.000

Attack Time

0.0 ms to 1000.0 ms

10.0 ms

Filter Hold Time

0 seconds to 9 hours

00:00:00; Disabled

Fixed Filter Parameter

Settings Range

Default Setting

Frequency

20 Hz to 20 kHz

1000.0 Hz

Q

1.000 to 65.000

30.000

Cut

Up to 30 dB cut

0.0 dB

DMP 128 • Software Control

67