FBs Fixed Filters tab
Fixed filters are notch filters with an adjustable center frequency and Q, and up to 30 dB
of cut. The fixed filters are typically set by converting dynamic filters to fixed, however
adjustments to filter parameters can be manually made from the Fixed Filters tab.
Fixed Filters are inactive and the filter type is set to Unused by default (see rows 4 and 5
in figure 40).
Figure 40.
FBS Fixed Filters Tab
No filter parameters are displayed when the filter type is set to Unused. As a filter is
moved to the fixed filter tab from a dynamic filter, the filter becomes active and displays
Notch as the filter type. The parameters copied from the dynamic filter are displayed in
the same line. Once a fixed filter is active, settings can be modified or adjusted as needed.
Fixed filters can also be individually bypassed by clicking Bypass.
FBS Settings Ranges and Fixed Filter Defaults
FBS Parameter
Settings Range
Default Setting
Frequency
20 Hz to 20 kHz
N/A
Q
5.000 to 65.000
30.000
Attack Time
0.0 ms to 1000.0 ms
10.0 ms
Filter Hold Time
0 seconds to 9 hours
00:00:00; Disabled
Fixed Filter Parameter
Settings Range
Default Setting
Frequency
20 Hz to 20 kHz
1000.0 Hz
Q
1.000 to 65.000
30.000
Cut
Up to 30 dB cut
0.0 dB
DMP 128 • Software Control
67