B&K Precision 9171-9174 - Manual User Manual

Page 145

Advertising
background image

133


VOLTage/VOLT2

Note:

VOLT2 command is for dual channel models only.

Description:

Configures/Queries the VSET voltage setting. For dual

channel models, use VOLT2 command for channel 2.

Syntax:

VOLTage<SP><voltage>

VOLT2<SP><voltage>

VOLTage?

VOLT2?

<voltage> - 0 – max. rated voltage output

Example:

VOLT2 12.000

Sets the second channel VSET voltage to 12.000 V on

a dual channel model.

Query:

VOLT?

Return String:

12.000

Format:

<NRf>


VOUT?/VOUT2?

Note:

VOUT2 command is for dual channel models only.

Description:

Queries the measured/readback voltage output value.

For dual channel models, use VOUT2 command for

channel 2.

Syntax:

VOUT?

VOUT2?

Example:

VOUT?

Return String:

10.002

Output voltage measured is 10.002 V.

Format:

<NRf>


VSET/VSET2

Description:

This command is the same as VOLTage/VOLT2

command. See VOLTage/VOLT2 for details.

Example:

VSET?

VSET 12.345

Format:

<NRf>