Defining segment information – Watlow ANAWIN 2 User Manual

Page 53

Advertising
background image

Setting Channel Parameters

AnaWin User’s Guide 5-13

Show Segs: Select Show Segs to display the segment boundaries of the
profile. You can display up to 20 segments.

Segs Displayed: Use the First and Last fields in the Segs Displayed
panel to specify which segments you want to view.

The bottom portion of the Ramp Soak Edit screen displays a table of
information and editable parameters for the running segments in the
profile. Use the scroll bar at the bottom of the screen to scroll through
the segments. Refer to “Defining Segment Information,” below, for
details about using the segment table.

Defining Segment Information

Each column in the table at the bottom of the Ramp Soak Edit screen
represents a segment. The rows display the following:

Segment #: The Segment # row displays the segment number. This is a
read-only field.

Name: Use the Name row to enter a name for the segment.

Seg Time: Use the Seg Time row to enter a time (duration) for the
segment. Segment time is unitless —it depends on how the ramp/soak
time base
field is set in the controller at the time the profile is run. The
time base is either hours:minutes or minutes:seconds.

Total Time: The Total Time row displays the cumulative time for all
the segments up to the edited segment. This is a read-only field.

Setpoint: Use the Setpoint row to enter the setpoint you want at the end
of the segment.

Tolerance: Use the Tolerance row to enter the segment setpoint’s
tolerance. If the difference between the PV and the setpoint is greater
than the tolerance, the loop goes into tolerance wait state until the PV is
back within setpoint tolerance. If you do not want to set a tolerance for
the segment, enter 0 in this field.

Advertising