Detail F – Left Limit Switch Roller

Limit
Switch
Roller

Detail G – Manually Open Curtain

4. With the curtain at the bottom limit, turn the Left Limit Switch’s 3 Setting Rings

until the Limit Switch Roller [22] snaps into place in the Switch Groove [21].
See Detail F.


5. When the three switch grooves [21] are in line, the three Adjusting Screws in the adjusting

rings [9, 11, 13] are also in one line. Tighten the screws in the setting rings [9, 11, 13] using a
1.5 mm hex wrench. Torque to 1.3 to 1.5 in.-lb.


6. Open the Curtain. See Detail G.





7. Turn the 3 Setting Rings of the Right Limit Switch like in Step 4.

8. Tighten screws in setting rings [15, 17, 19] to 1.3 to 1.5 in.-lb.

9. Verify the operation of the Limit Switch Settings by operating the curtain from the controller.