Flush System

It is very important to flush the system. After completing system assembly, follow
steps below in order to flush out debris from pipes.

1.

Open ball valve at end of system. See diagram above.

2.

Turn on water. Fill reservoir to fill line. Fill the Strainer Basket.

WARNING: Do not over-tighten the Strainer Basket lid. Hand-Tight ONLY.

3.

Turn on pump to flush out system.

4.

After flushing system, turn off pump.

5.

Close ball valve at end of spray line.

6.

Clean In-Line Filter.

7.

Resume normal operation

NOTES:

1. Expect about 70 gallons of water per 50

feet of reservoir pipe.

2. Lubricate the strainer basket lid seal with

Vaseline to ensure vacuum-tight seal.