HP EVA P6000 Storage User Manual
Page 181
Table 27 Error Messages (continued)
How to correct
Meaning
Status code value
In the following cases, the message
can occur because the operation is
The supplied handle is invalid. This can
indicate a user error, program error, or a
storage cell in an uninitialized state.
In the following cases, the storage cell is in
an uninitialized state, but no action is
required:
12
Invalid Parameter handle
not allowed when the storage cell is
in an uninitialized state. If you see
these messages, initialize the storage
cell and retry the operation.
Storage cell set device addition policy
Storage cell discard (informational
message):
Storage cell set name
Storage cell look up object count
(informational message):
Storage cell set time
Storage cell set volume replacement
delay
Storage cell look up object (informational
message):
Storage cell free command lock
Storage cell set console lun id
Report the error to product support.
The supplied identifier is invalid. This can
indicate a user or program error.
13
Invalid Parameter Id
Report the error to product support.
This error is no longer supported.
14
Invalid Quorum Configuration
Case 1: Report the error to product
support.
The supplied target handle is invalid. This
can indicate a user or program error (Case
1),
15
Invalid Target Handle
Case 2: To add additional capacity
to the disk group, use the management
or
software to add disks by count or
capacity.
Volume set requested usage (Case 2):
The operation could not be completed
because the disk has never belonged to a
disk group and therefore cannot be added
to a disk group.
Report the error to product support.
The supplied target identifier is invalid. This
can indicate a user or program error.
16
Invalid Target Id
Report the error to product support.
This error is no longer supported.
17
Invalid Time
Report the error to product support.
The operation could not be completed
because one or more of the disk media was
inaccessible.
18
Media is Inaccessible
Report the error to product support.
The Fibre Channel port specified is not valid.
This can indicate a user or program error.
19
No Fibre Channel Port
Report the error to product support.
There is no firmware image stored for the
specified image number.
20
No Image
The disk device must be in either
maintenance mode or in a reserved
The disk device is not in a state to allow the
specified operation.
21
No Permission
state for the specified operation to
proceed.
Create a storage cell and retry the
operation.
The operation requires a storage cell to exist.
22
Storage system not initialized
Report the error to product support.
The Fibre Channel port specified is either
not a loop port or is invalid. This can
indicate a user or program error.
23
Not a Loop Port
Report the error to product support.
This error is no longer supported.
24
Not a Participating Controller
181