Controller status leds – HP EVA P6000 Storage User Manual

Page 25

Advertising
background image

Table 1 HSV340/360 controller port status indicators

Description

Port

Fibre Channel host ports

Green — Normal operation

Amber — No signal detected

Off — No SFP

1

detected or the Direct Connect HP P6000 Control Panel

setting is incorrect

Fibre Channel device ports

Green — Normal operation

Amber — No signal detected or the controller has failed the port

Off — No SFP

1

detected

1

On copper Fibre Channel cables, the SFP is integrated into the cable connector.

Table 2 HSV340/360 FC-iSCSI controller port status indicators

Description

Port

Fibre Channel switch ports

Green on — Normal operation or loopback port

Green flashing — Normal online I/O activity

Amber on — Faulted port, disabled due to diagnostics or Portdisable
command

Amber flashing — Port with no synchronization, receiving light but not yet
online or segmented port

Off — No SFP

1

, no cable, no license detected.

Fibre Channel device ports

Green — Normal operation

Amber — No signal detected or the controller has failed the port

Off — No SFP

1

detected

1

On copper Fibre Channel cables, the SFP is integrated into the cable connector.

Controller status LEDs

Figure 8 (page 25)

shows the location of the controller status LEDs;

Table 3 (page 25)

describes

them.

NOTE:

Figure 8 (page 25)

shows an FC-iSCSI controller, however the LEDs for the FC, FC-iSCSI,

and iSCSI/FCoE controllers are identical, unless specifically noted.

Figure 8 Controller status LEDs

Table 3 Controller status LEDs

Indication

LED

Item

Blue LED identifies a specific controller within the enclosure or
identifies the FC-iSCSI or iSCSI/FCoE module within the controller.

1

Green LED indicates controller health. LED flashes green during
boot and becomes solid green after boot.

2

Controller enclosure

25

Advertising