Modifying a configuration – HP EVA P6000 Storage User Manual
Page 267

Modifying a configuration
The module has the following major areas of configuration:
•
Management port configuration requires the use of the following commands:
The
◦
◦
The
“show mgmt command” (page 253)
•
iSCSI port configuration requires using the following commands:
The
“set iSCSI command” (page 235)
◦
◦
The
“show iSCSI command” (page 247)
•
Virtual port groups configuration requires the following commands:
The
“set VPGroups command” (page 239)
◦
◦
The
“show VPGroups command” (page 262)
•
LUN mapping requires the use of the
“show lunmask command” (page 252)
Saving and restoring iSCSI or iSCSI/FCoE controller configurations
Saving and restoring a configuration helps protect your work. You can also use a saved
configuration as a template for configuring other modules.
Persistent data consists of system settings, virtual port group settings, LUN mappings, discovered
FC targets, and discovered iSCSI initiators. To save a module’s configuration and persistent data:
1.
Generate a file (HP_StorageWorks_MEZ50_FRU.bin) containing the saved data (see page
2-12) , by entering the fru save CLI command.
This command stores the file locally on the module in an FTP directory.
2.
Transfer the saved data from the iSCSI or iSCSI/FCoE module to a workstation by executing
an FTP utility on a workstation.
The following example shows an FTP transfer to get the saved module configuration data:
c:\> ftp 172.17.137.102
Connected to 172.17.137.102.
220 (none) FTP server (GNU inetutils 1.4.2) ready.
User (172.17.137.102:(none)): ftp
331 Guest login ok, type your name as password.
Password: ftp
230 Guest login ok, access restrictions apply.
ftp> bin
200 Type set to I.
ftp> get HP_StorageWorks_MEZ50_FRU.bin
200 PORT command successful.
150 Opening BINARY mode data connection for 'HP_StorageWorks_MEZ50_FRU.bin'
(6168 bytes).
226 Transfer complete.
ftp: 6168 bytes received in 0.00Seconds 6168000.00Kbytes/sec.
ftp> quit
221 Goodbye.
Restoring iSCSI or iSCSI/FCoE module configuration and persistent data
1.
Transfer the saved data from a workstation to the iSCSI or iSCSI/FCoE module by executing
an FTP utility on the workstation.
The following example shows an FTP transfer to put previously saved module configuration
data on the module:
c:\> ftp 172.17.137.102
Connected to 172.17.137.102.
Working with iSCSI or iSCSI/FCoE module configurations 267