HP XP Continuous Access Software User Manual

Page 172

Advertising
background image

172

HP StorageWorks Disk Array XP RAID Manager: User’s Guide

M=W

(Valid for PSUS state only)

In the P-VOL case, this

designates “suspended” with S-VOL R/W enabled.

In the S-VOL case, this designates that the S-VOL can
accept writes.

M=N

(Valid for COPY/RCPY/PAIR/PSUE state) A listed
volume means that reading is disabled.

Example

This example shows a pairresync on group

VG01

. pairdisplay shows two

volumes in the COPY state. The

copy%

value indicates how much of the

P-VOL is in sync with the S-VOL.

# pairresync –g VG01

# pairdisplay -g VG01 –fc -l

Group PairVol(L/R) (Port#,TID,LU-M),Seq#,LDEV#.P/S,Status,Copy%,P-LDEV# M

VG01 d1(L) (CL2-P , 0, 0-0)35641 58..P-VOL COPY, 89 61 -

VG01 d2(L) (CL2-P , 0, 1-0)35641 59..P-VOL COPY, 96 62 -

Error Codes

The table lists specific error codes for the pairresync command.

Category

Error Code

Error Message

Value

Volume status
unrecoverable

EX_ENQVOL

Unmatched volume status within the group

236

EX_INCSTG

Inconsistent status in group

229

EX_INVVOL

Invalid volume status

222

EX_INVSTP

Invalid pair status

228