HP XP Continuous Access Software User Manual
Page 390
390
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
HORCM_INST
#dev_group ip_address service
VG01 HOSTA horcm0
The UDP port name for HORCM communication in
"SYS$SYSROOT:[000000.TCPIP$ETC]SERVICES.DAT"
is defined
as shown in the example below.
horcm0 30001/udp
horcm1 30002/udp
Starting “horcm 0” and “horcm 1” as detached processes
$ run /DETACHED SYS$SYSTEM:LOGINOUT.EXE
/PROCESS_NAME=horcm0 -
_$ /INPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]
loginhorcm0.com
-
_$ /OUTPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run0.out -
_$ /ERROR=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run0.err
%RUN-S-PROC_ID, identification of created process is
00004160
$
$
$ run /DETACHED SYS$SYSTEM:LOGINOUT.EXE
/PROCESS_NAME=horcm1 -
_$ /INPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]
loginhorcm1.com
-
_$ /OUTPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run1.out -
_$ /ERROR=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run1.err
%RUN-S-PROC_ID, identification of created process is
00004166
You will be able to verify that HORCM daemon is running as a detached
process by using the SHOW PROCESS command.
#dev_group
dev_name
port#
TargetID
LU#
MU#
VG01
oradb1
CL1-H
0
3
0
VG01
oradb2
CL1-H
0
5
0
VG01
oradb3
CL1-H
0
7
0