HP ESL E-series Tape Libraries User Manual
Page 146
Critical events
Event ID
The hardware is obstructed.
0x22f
Horizontal hardware failed due to robotics FPGA failure.
0x230
The hardware home position is drifting.
0x231
Horizontal hardware failure. Scanner was unable to detect optical target
during calibration.
0x232
While pushing a cartridge into a bin or drive, the extension axis never
made contact with any object.
0x233
The sensor was occluded unexpectedly during calibration, inventory or
pick/place.
0x234
Horizontal hardware failure. Electronics necessary for hardware to
function is not present.
0x235
Hardware internal failure.
0x236
Depth hardware failure of motor encoder.
0x237
Home sensor/flag failure.
0x238
Hardware did not reach appropriate position. The axis path could be
obstructed.
0x239
Hardware did not reach appropriate position.
0x23a
The hardware is obstructed
0x23b
Depth hardware failed due to robotics FPGA failure.
0x23c
The hardware home position is drifting.
0x23d
Depth hardware failure. Scanner was unable to detect optical target
during calibration.
0x23e
While pushing a cartridge into a bin or drive, the extension axis never
made contact with any object.
0x23f
The sensor was occluded unexpectedly during calibration, inventory or
pick/place.
0x240
Depth hardware failure. Electronics necessary for hardware to function
is not present.
0x241
Hardware internal failure.
0x242
CLM hardware failure of motor encoder.
0x243
Check home sensor connector and flag.
0x244
Hardware did not reach appropriate position. The axis path could be
obstructed.
0x245
Hardware did not reach appropriate position.
0x246
The hardware is obstructed.
0x247
Event reporting