Stop button, Inserting tape cartridges into a fixed load port, Diagnostics confirmation remaining offline – HP ESL E-series Tape Libraries User Manual
Page 69

To perform a diagnostic test:
1.
Take the library off-line.
a.
Press the Ops button on the OCP to access the Operations screen.
b.
Select Cabinet.
c.
Use the Up and Down arrows to select Offline, then press the Select button.
d.
Press the Yes button when the Confirmation screen appears.
e.
Press Back to return to the main screen.
2.
Use the Up and Down arrows to select Diags, then press the Select button. Use the Up and Down
arrows to select the diagnostic test to perform and press Select.
3.
If you did not take the library off-line, the OCP displays a notification (see
).
Figure 51 Diagnostics confirmation remaining offline
.
4.
Select Yes to take the library off-line, then run the test.
The diagnostic test executes and the OCP displays a status screen indicating the test progress.
When the test completes, the test result is shown next to the completed test.
5.
When you are finished performing diagnostic tests, press Back to return to the Menu screen.
Stop button
The STOP button located in the bottom right portion of the OCP is available from every OCP screen.
This button stops the cabinet robot from moving. To start the robotics, press the Start button.
Inserting tape cartridges into a fixed load port
With load ports enabled, tape cartridges are inserted into fixed magazines on the first column of the
left panel and the first two columns of the right panel. Fixed magazines hold 18 Ultrium cartridges
or 16 SDLT cartridges.
To insert a tape cartridge into a fixed magazine:
1.
Prepare the tape cartridges to be inserted by affixing a barcode label and write-protecting or
write-enabling each cartridge as appropriate.
For more information about these procedures, see
.
HP StorageWorks ESL E-Series Tape Library
69