304 Managing the Disk Array Using Array Manager 60

Performing Disk Array Maintenance

At some point during operation of the disk array, you may need to perform maintenance
tasks that involve error recovery and problem isolation. This section describes the tasks
involved in maintaining the disk array.

Locating Disk Modules

Array Manager 60 provides the means of identifying a disk module by flashing its amber
Fault LED. You can flash the Fault LED on an individual disk, or on all the disks in the
array. It is advisable to positively identify a failed disk before removing it from the disk
array. Removing the wrong disk could cause the data on the LUN to become unavailable.

To locate a disk module, type:

amutil <option> <ArrayID>

option identifies the disk modules you want to identify.

Table 39

lists valid

options.

Command Example

The following example flashes the Fault LED on disk 3 on channel 2 in disk array
data_center_1:

amutil -f 2:3 data_center_1

Table 39

Command Options for Locating Disk Array Components

Option

Description

-f channel:ID

Flash the

Fault

LED on the specified disk. A disk is identified by both

channel (1- 6) and SCSI ID (0 - 4, 8 - 12).

-F

Flash the

Fault

LEDs on all the disks in the disk array.

-s

Stop flashing the disk

Fault

LEDs. This option works for both a single

disk and multiple disks.