HP Surestore Disk Array 12h and FC60 User Manual
Page 336

336 Status Conditions and Sense Code Information
40
NN
Diagnostic Failure on Component NN (0x80 - 0xFF)
The controller has detected the failure of an internal controller
component. This failure may have been detected during opera-
tion as well as during an on-board diagnostic routine. The val-
ues of NN supported in this release of the software are listed
below.
80 - Processor RAM
81 - RAID Buffer
82 - NVSRAM
83 - RAID Parity Assist (RPA) chip or cache holdup battery
84 - Battery Backed NVSRAM or Clock Failure
91 - Diagnostic Self Test failed non-data transfer components
test
92 - Diagnostic SelfTest failed data transfer components test
93 - Diagnostic SelfTest failed drive Read/ Write Buffer data
turnaround test
94 - Diagnostic Self Test failed drive Inquiry access test
95 - Diagnostic Self Test failed drive Read/ Write data turn-
around test
96 - Diagnostic Self Test failed drive Self Test
43
00
Message Error
The controller attempted to send a message to the host, but the
host responded with a Reject message.
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier
Interpretation