310 Managing the Disk Array Using Array Manager 60

actual ArrayID must be used here. An alias cannot be used because alias names are not
recorded in the log file.

Command Example

The following example displays the major event log entries for disk array rack_1. The log
entries displayed are limited to only critical entries, and entries made after 0900 on 15 May
2000.

amlog -s 05150000 -t mel -c rack_1

Sample Log Entries

The following is a sample of a major event log entry.

Major event log for Subsystem 001100A0B8060166 at Wed Nov 29

17:38:27 2000

Sequence Number = 14

Time Stamp = Wed Nov 29 17:38:19 2000

Event Type = Global Hot Spare Not Large Enough (224F)

Event Category = Notification

Component Type = Disk

Enclosure = 5

Slot (0-based) = 3

Event Priority = Informational

The following is a sample of an Asynchronous Event Log entry:

Controller log sense for Subsystem 001100A0B8060166 at Mon Dec 4

12:51:34 2000

Controller Time Stamp = 032307 083318

FRU Code = 0x08

FRU Code Qualifier = 0x8142

Sense Key = 0x06

Additional Sense Code = 0x3F

Add Sense Code Qual = 0xC7

Decoded Field Replaceable Unit Information:

FRU Group = Sub-Enclosure Group

FRU ID Setting = 1

FRU Type = Power Supply