HP Surestore Disk Array 12h and FC60 User Manual
Page 310

310 Managing the Disk Array Using Array Manager 60
actual ArrayID must be used here. An alias cannot be used because alias names are not
recorded in the log file.
Command Example
The following example displays the major event log entries for disk array rack_1. The log
entries displayed are limited to only critical entries, and entries made after 0900 on 15 May
2000.
amlog -s 05150000 -t mel -c rack_1
Sample Log Entries
The following is a sample of a major event log entry.
Major event log for Subsystem 001100A0B8060166 at Wed Nov 29
17:38:27 2000
Sequence Number = 14
Time Stamp = Wed Nov 29 17:38:19 2000
Event Type = Global Hot Spare Not Large Enough (224F)
Event Category = Notification
Component Type = Disk
Enclosure = 5
Slot (0-based) = 3
Event Priority = Informational
The following is a sample of an Asynchronous Event Log entry:
Controller log sense for Subsystem 001100A0B8060166 at Mon Dec 4
12:51:34 2000
Controller Time Stamp = 032307 083318
FRU Code = 0x08
FRU Code Qualifier = 0x8142
Sense Key = 0x06
Additional Sense Code = 0x3F
Add Sense Code Qual = 0xC7
Decoded Field Replaceable Unit Information:
FRU Group = Sub-Enclosure Group
FRU ID Setting = 1
FRU Type = Power Supply