HP Surestore Disk Array 12h and FC60 User Manual

Page 51

Advertising
background image

Disk Array High Availability Features 51

Produ

ct Des

c

ript

ion

fails. RAID-0 provides enhanced performance through simultaneous I/Os to multiple disk
modules. Software mirroring the RAID-0 group provides high availability.

Figure 18

illustrates the distribution of user and parity data in a four-disk RAID 0 LUN. The

the stripe segment size is 8 blocks, and the stripe size is 32 blocks (8 blocks times 4 disks).
The disk block addresses in the stripe proceed sequentially from the first disk to the
second, third, and fourth, then back to the first, and so on.

Figure 18

RAID 0

LUN

RAID 1

RAID 1 uses mirroring to achieve data redundancy. RAID 1 provides high availability and
good performance, but at the cost of storage efficiency. Because all data is mirrored, a
RAID 1 LUN has a storage efficiency of 50%.

A RAID 1 LUN consists of exactly two disks configured as a mirrored pair. One disk is the
data disk and the other is the disk mirror. The disks in a RAID 1 LUN are mirrored by the
disk array hardware, which automatically writes data to both the data disk and the disk
mirror. Once bound into a RAID 1 mirrored pair, the two disks cannot be accessed as

Advertising