Using the library when robotics are not ready – HP StoreEver ESL G3 Tape Libraries User Manual

Page 105

Advertising
background image

Administrative users can lock or unlock the I/E station doors using an option from the Operations
menu.
To lock or unlock the I/E station:

1.

From the View menu or in the Managed Views region of the LMC, click the name of the
physical library.

2.

Click Operations

→I/E Station.

NOTE:

The I/E Station # column lists the I/E station number for each door. All single door

I/E stations are numbered starting with 1 at the control module. All double door I/E stations
are numbered with a number and a letter, such as 2A and 2B, the module number (1-8), with
A as the left I/E station and B the right I/E station.

3.

To change the state of the I/E station doors, do one of the following:

To lock an I/E station door, in the appropriate Action column, click Lock.

To unlock an I/E station door, in the appropriate Action column, click Unlock.

4.

To return to the main console, click Close.

Using the library when robotics are not ready

When the library robotics are not yet ready to accept commands, features of the LMC are still
available while others are not. This can happen during startup, reboot, or while the library is
running. During run time, for example, the robotics will become unavailable if someone opens and
closes an access door without pressing the Robotics Enabled button.

Whenever robotics become disabled, a message appears in the Activity area on the main LMC
display that states, Warning: The Robotics are not Enabled. Users can log on locally
or remotely while the robotics are disabled.

Table 16 (page 105)

lists the menu commands that are available when the robotics become disabled

either before system discovery can occur or after system discovery has occurred. As the table
shows, significantly fewer menu commands are available when the library is started up or rebooted
and the robotics become disabled before system discovery occurs.

NOTE:

Menu commands not listed in the table are not available when the robotics become

disabled, regardless of when the robotics become disabled. Unavailable menu commands are
grayed out on the LMC.

Table 16 Menu commands when robotics are disabled

Before discovery

After discovery

Available menu commands when robotics become disabled

X

X

Operations

→Change Mode (for shutdown only)

X

X

Operations

→Log Off

X

Monitor

→Drives >

X

Monitor

→I/E Station

X

Monitor

→Slots

X

Monitor

→Media

X

Monitor

→Sensor

X

Monitor

→Users

X

Setup

→Setup Wizard

X

Setup

→Partitions

X

X

Setup

→Network Configuration (from OCP only)

Using the library when robotics are not ready 105