3-2 Line Contactor Short Circuit

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

321

LINE CONTACTOR
MISWIRED ON OR WELDED

The Line contactor is off, but the System
Module is being energized.

• Check wiring of contactor.
• Check resistance between the studs of the contactor while dis-

connected from the machine.

• Check contactor main contact wiring to battery (+) terminal and

power module terminal B+.

• Check continuity between contactor connector pin 1 and ground

board socket J1-13.

• Check continuity between contactor connector pin 2 and ground

module J1-32.

• Measure voltage between power model B+ and B- terminals. If

24V is present, replace line contactor.

• Replace power module.
• HEALTH (Status LED) - ON

326

AUXILIARY RELAY - SHORT
TO BATTERY

The Auxiliary Relay has not been ener-
gized by the System Module, but J1-28
is energized.

• The Auxiliary Relay's contacts or coil may be mis-wired
• There is a wire harness issue that allows +B to reach J1-28.

This situation will cause the batteries to discharge while the vehi-
cle is turned off.

• Alternately, the Auxiliary Relay is faulty, replace Auxiliary Relay.
• HEALTH (Status LED) - ON

3-3 Ground Output Driver

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

333

LIFT UP VALVE - SHORT TO
BATTERY

Voltage from an external source was
detected on the Lift Up Solenoid (J2-17
NUV).

• Check for continuity through this circuit. The lift up solenoid resis-

tance should measure about 30 Ohms. The lift up solenoid is
powered with 24V from ground board J2-1, and its ground is to
ground board J2-17.

• Inspect the wiring for physical damage.
• Replace ground board.
• HEALTH (Status LED) - ON

334

LIFT UP VALVE - OPEN CIR-
CUIT

Current flow to the Lift Up Solenoid was
not detected (J2-17 NUV).

• Check for continuity through this circuit. The lift up solenoid resis-

tance should measure about 30 Ohms. The lift up solenoid is
powered with 24V from ground board, and its ground is to ground
board.

• Inspect the wiring for physical damage.
• Replace ground board.
• HEALTH (Status LED) - ON

335

LIFT DOWN VALVE - SHORT
TO BATTERY

The power module detected voltage
while the lift down solenoid was com-
manded off. (J2-2 PDV or J2-16 NDV)

• Check ANALYZER -> MACHINE SETUP -> ELEV PROX is set to

NOT INSTALLED

• Check for continuity through this circuit. The lift down solenoid

resistance should measure about 20 Ohms. The lift down sole-
noid is powered (PWM) by ground board J2-2, and its ground is
to ground board J2-16.

• Inspect the wiring for physical damage.
• Replace ground board.
• HEALTH (Status LED) - ON