SECTION 1 - SPECIFICATIONS

1-6

– JLG Lift –

3121253

1.8 OPERATOR MAINTENANCE

NOTE: The following numbers correspond to those in Fig-

ure 1-2., Operator Maintenance and Lubrication
Diagram.

LUBRICATION INTERVALS ARE BASED ON MACHINE OPERATION
UNDER NORMAL CONDITIONS. FOR MACHINES USED IN MULTI-
SHIFT OPERATIONS AND/OR EXPOSED TO HOSTILE ENVIRON-
MENTS OR CONDITIONS, LUBRICATION FREQUENCIES MUST BE
INCREASED ACCORDINGLY.

1. Swing Bearing

Lube Point(s) - Remote Fitting
Capacity - A/R
Lube - BG
Interval - Every 3 months or 150 hrs of operation
Comments - Apply grease and rotate in 90 degree
intervals until bearing is completely lubricated

2. Swing Bearing/Worm Gear Teeth

Lube Point(s) - Grease Fittings
Capacity - A/R
Lube - BG
Interval - A/R

Lube Point(s) - Grease Fittings
Capacity - A/R
Lube - Mobile SHC 007
Interval - A/R

DO NOT OVERGREASE BEARINGS. OVERGREASING BEARINGS
WILL RESULT IN DAMAGE TO OUTER SEAL IN HOUSING.

Table 1-10. Lubrication Specifications

KEY

SPECIFICATIONS

MPG

Multipurpose Grease having a minimum dripping point of
350 degrees F. Excellent water resistance and adhesive
qualities; and being of extreme pressure type (Timken OK
40 pounds minimum).

EPGL

Extreme Pressure Gear Lube (oil) meeting API Service
Classification GL-5 or Mil-Spec Mil-L-2105.

HO

Hydraulic Oil. Mobil DTE-11M

BG*

Bearing Grease (JLG Part No. 3020029) Mobilith SHC
460.

LL

Synthetic Lithium Lubricant, Gredag 741 Grease. (JLG
Part No. 3020022)

*MPG may be substituted for these lubricants, if necessary, but ser-
vice intervals will be reduced.