1.8 OPERATOR MAINTENANCE
NOTE: The following numbers correspond to those in Fig-
ure 1-2., Operator Maintenance and Lubrication
Diagram.
LUBRICATION INTERVALS ARE BASED ON MACHINE OPERATION
UNDER NORMAL CONDITIONS. FOR MACHINES USED IN MULTI-
SHIFT OPERATIONS AND/OR EXPOSED TO HOSTILE ENVIRON-
MENTS OR CONDITIONS, LUBRICATION FREQUENCIES MUST BE
INCREASED ACCORDINGLY.
1. Swing Bearing
Lube Point(s) - Remote Fitting
Capacity - A/R
Lube - BG
Interval - Every 3 months or 150 hrs of operation
Comments - Apply grease and rotate in 90 degree
intervals until bearing is completely lubricated
2. Swing Bearing/Worm Gear Teeth
Lube Point(s) - Grease Fittings
Capacity - A/R
Lube - BG
Interval - A/R
Lube Point(s) - Grease Fittings
Capacity - A/R
Lube - Mobile SHC 007
Interval - A/R
DO NOT OVERGREASE BEARINGS. OVERGREASING BEARINGS
WILL RESULT IN DAMAGE TO OUTER SEAL IN HOUSING.
Table 1-10. Lubrication Specifications
KEY
SPECIFICATIONS
MPG
Multipurpose Grease having a minimum dripping point of
350 degrees F. Excellent water resistance and adhesive
qualities; and being of extreme pressure type (Timken OK
40 pounds minimum).
EPGL
Extreme Pressure Gear Lube (oil) meeting API Service
Classification GL-5 or Mil-Spec Mil-L-2105.
HO
Hydraulic Oil. Mobil DTE-11M
BG*
Bearing Grease (JLG Part No. 3020029) Mobilith SHC
460.
LL
Synthetic Lithium Lubricant, Gredag 741 Grease. (JLG
Part No. 3020022)
*MPG may be substituted for these lubricants, if necessary, but ser-