SECTION 6 - JLG CONTROL SYSTEM
6-32
– JLG Lift –
3121253
TEST ALL INPUTS?
Prompts whether to check every operator input. If ESC is pressed, the system test ends.
If ENTER is pressed, each operator input is prompted for in turn.
In platform mode, operator inputs are tested in the order: POSITRAC, MAIN U, MAIN D, SWING L, SWING R,
LEVEL U, LEVEL D, PUMP POT, CREEP, ROTATE L, ROTATE R, TWR U, TWR D, JIB U, JIB D, JIB L, JIB R,
TELE I, TELE O, DRIVE FWD, DRIVE REV, STEER L, STEER R
In ground mode, operator inputs are tested in the order: ROTATE L, ROTATE R, LEVEL U, LEVEL D,
JIB U, JIB D, JIB L, JIB R, TELE I, TELE O, MAIN U, MAIN D, TWR U, TWR D, SWING L, SWING R
NOTE: the jib switches are not tested if JIB = NO.
Prompts displayed during the operator input test include:
CLOSE switch name
The named switch should be closed.
OPEN switch name
The named switch should be opened.
joystick name direction TO MAX
The named joystick should be pushed to its full extent in the named direction.
joystickname direction TO MIN
The named joystick should be returned to neutral from the named direction.
PUMP POT TO MAX
The pump pot should be turned to maximum.
PUMP POT TO MIN
The pump pot should be turned to minimum.
MULTIPLE CLOSURE
More than one operator input is closed; if only one has been operated, there could be a short between two
inputs.
TESTS COMPLETE
Indicates that the system test is complete. Any problems reported should have been noted and should now be recti-
fied.
Press ESC to return to the RUN SYSTEM TEST Analyzer menu.
Table 6-6. System Test Messages