M150 AND M200 ENGINE ERROR CODES

Form # 169017 / 169087 / 169095

230

Revision C

J1939 SPN

Description

J1939

SPN

J1939

FMI

Lamp
Color

Cummins

Engine

Code

CAT

Engine

Code

Cummins / Caterpillar Description

14 Red 292

Auxiliary Temperature Sensor Input # 1 Circuit - Special

Instructions

Accelerator

Pedal Low Idle

Switch

558

2

Amber

431

91

Accelerator Pedal or Lever Idle Validation Circuit - Data Erratic,

Intermittent, or Incorrect

2 155

774

Data erratic, intermittent, or incorrect

4

Amber

551

Accelerator Pedal or Lever Idle Validation Circuit - Voltage Below

Normal, or Shorted to Low Source

13

Red

432

Accelerator Pedal or Lever Idle Validation Circuit - Out of

Calibration

System

Diagnostic

code # 1

611

3

Amber

2185

Sensor Supply Voltage #4 Circuit - Voltage Above Normal, or

Shorted to High Source

4

Amber

238

Sensor Supply Voltage #3 Circuit - Voltage Below Normal, or

Shorted to Low Source

Fuel Inlet

Meter Device

16

Amber

2292

Fuel Inlet Meter Device - Data Valid but Above Normal Operational

Range - Moderately Severe Level

18

Amber

2293

Fuel Inlet Meter Device flow demand lower than expected - Data

Valid but Below Normal Operational Range - Moderately Severe

Level

Electronic

Control
Module

31

Amber

757

Electronic Control Module data lost - Condition Exists

System

Diagnostic

Code # 2

612

2

Red

115

Engine Speed / Position Sensor Circuit lost both of two signals from

the magnetic pickup sensor - Data Erratic, Intermittent, or incorrect

Red Stop

Lamp

623 4 Amber 244

Red Stop lamp Driver Circuit - Voltage Below Normal, or Shorted to

Low Source

Power Supply

627

2

Amber

434

Power Lost without Ignition Off - Data Erratic, Intermittent, or

Incorrect

Controller #1

629

12

Red

111

Engine Control Module Critical internal failure - Bad intelligent

Device or Component

Calibration

Memory

630

2

Amber

341

268

Engine Control Module data lost - Data Erratic, Intermittent, or

Incorrect

13

Red

342

Electronic Calibration Code Incompatibility - Out of Calibration

31

Amber

2217

ECM Program Memory (RAM) Corruption - Condition Exists

Engine

software

631 2 415

253

Data incorrect

Fuel Control

Valve #1

633

31

Amber

2311

Fueling Actuator #1 Circuit Error - Condition Exists

Primary to
secondary

speed signal

637 11 143

261

Calibration fault

SAE J1939

Datalink

639

9

Amber

285

247

SAE J1939 Multiplexing PGN Timeout Error - Abnormal Update

Rate

13

Amber

286

SAE J1939 Multiplexing Configuration Error - Out of Calibration

Variable

Geometry

Turbocharger

641

3

Amber

2385

VGT Actuator Driver Circuit - Voltage Above Normal, or Shorted to

High Source

4

Amber

2384

VGT Actuator Driver Circuit - Voltage Below Normal, or Shorted to

Low Source

Turbo

Wastegate

646

5 177

526

Solenoid Current Low

6 177

526

Solenoid Current High

Injector

Cylinder #01

651

5

Amber

322

1

Injector Solenoid Cylinder #1 Circuit - Current Below Normal, or

Open Circuit

6

N/A

1

Injector Current High

7

Amber

1139

1

Injector Cylinder #1 - Mechanical System Not Responding Properly

or Out of Adjustment

Injector

Cylinder #02

652

5

Amber

331

2

Injector Solenoid Cylinder #2 Circuit - Current Below Normal, or

Open Circuit

6

N/A

2

Injector Current High

7

Amber

1141

2

Injector Cylinder #2 - Mechanical System Not Responding Properly

or Out of Adjustment

Injector

Cylinder #03

653

5

Amber

324

3

Injector Solenoid Cylinder #3 Circuit - Current Below Normal, or

Open Circuit

6

N/A

3

Injector Current High

Advertising