Rockwell Automation 7000 DPI Wireless Interface Module User Manual
Page 73
Wireless Flash Updating DPI Devices
C-11
Figure C.20 Executing Flash Update Completed Screen
Click Close to exit the Flash Update Completed screen. The Device
Firmware Changed dialog box (
) will appear.
Figure C.21 Device Firmware Changed Dialog Box
9. Depending on the device being flash updated, do one of the following:
–
When flashing a drive or peripheral (not the WIM), click Yes.
DriveExplorer will re-establish the wireless connection to the
device. Then power cycle the drive to initialize the device with
the WIM.
–
When flashing the WIM, click No. The wireless connection to
the WIM breaks after the flash update, requiring a manual
reconnection. Use the Bluetooth Manager to re-establish the
wireless connection to the WIM. After wireless communication
is re-established, DriveExplorer will automatically reconnect to
the WIM.
10. With the DriveExplorer linear list screen (
) displayed,
select the device (for this example, a PowerFlex 70 drive). Then
select Explore > Device Properties… to verify that the Revision
number shown on the General tab screen matches the firmware
version flashed into the device.