Chapter 5 Program a Project Offline

Enter an SFC

1. Drag elements from the toolbar to the chart.

• A green dot shows a point to which the element will automatically connect if you release the mouse

button.

• Some toolbar buttons are active only after you select a corresponding element on the SFC. For

example, to add an action, first select a step.

• Drag an action until it is on top of the required step and then release the mouse button.

2. To manually connect elements, click corresponding pins. A green dot shows a valid connection point

3. To enter structured text, double-click a ? symbol. Then type the structured text and press Ctrl + Enter.