Watts R24-12-1111000 User Manual

Page 17

Advertising
background image

I. INTRODUCTION

The 3501 Reverse Osmosis Controller is designed to control and monitor the operating
parameters of a reverse osmosis water purification system. Information is displayed on a
back-lit liquid crystal display, and on individual light-emitting diodes (LEDs). Functions
and controls are operated through snap-dome switches (see Figure 1).


A.

Features


Temperature Compensated Conductivity Monitor


Water

Temperature

Monitor


Three Modes of Operation: Stand-by, Tank Feed, and Direct Feed


Pretreatment

Interlock


Tank

Full

Shutdown


Inlet

Valve

Control


Pump

Control


Low Feed Pressure Sensing with Automatic Reset


Autoflush with Adjustable Flush Time


Diverter

Valve

Output

B. Specifications

Power Requirements: The controller can operate with a power source of 115 or
230 VAC single phase. A multi-function power inlet is used to select the proper
input voltage.

Fuse:

1 amp 250 volt slow blow, located inside the power inlet receptacle.

Environment:

The controller can operate at a temperature from 0° to 60° C (32° to

140° F). Relative humidity must not exceed 95 percent.

Conductivity Monitor: The conductivity monitor measures the product water
quality and displays this information in micro-mhos/cm. The display is
temperature compensated to 25° C (770 F).

Advertising