Outputs 45 series – Watts T55-85MHP40 User Manual

Page 8

Advertising
background image

www.stenner.com

8

Outputs 45 series

Single Head

Maximum

Pump Tube

gallons

liters

gallons

liters

ounces

milliliters

liters

liters

milliliters

Model

Pressure

Number

per day

per day

per hour

per hour

per minute

per minute

per day

per hour

per minute

Adjustable

45MHP2*

100 psi/6.9 bar

#1

0.2 to 3.0

0.8 to 11.4

0.01 to 0.13

0.03 to 0.48

0.02 to 0.27

0.56 to 7.92

0.6 to 9.1

0.03 to 0.38

0.31 to 6.32

45M1

25 psi/1.7 bar

#1

Fixed Output
45MPHP2*

100 psi/6.9 bar

#1

3.0

11.4

0.13

0.48

0.27

7.92

9.1

0.38

6.32

45MP1

25 psi/1.7 bar

#1

Adjustable

45MHP10*

100 psi/6.9 bar

#2

0.5 to 10.0

1.9 to 37.9

0.02 to 0.42

0.08 to 1.58

0.04 to 0.89

1.32 to 26.32

1.5 to 30.3

0.06 to 1.26

1.04 to 21.04

45M2

25 psi/1.7 bar

#2

Fixed Output

45MPHP10*

100 psi/6.9 bar

#2

10.0

37.9

0.42

1.58

0.89

26.32

30.3

1.26

21.04

45MP2

25 psi/1.7 bar

#2

Adjustable

45MHP22*

100 psi/6.9 bar

#7

1.1 to 22.0

4.2 to 83.3

0.05 to 0.92

0.18 to 3.47

0.10 to 1.96

2.92 to 57.85

3.3 to 66.6

0.14 to 2.78

2.29 to 46.25

45M3

25 psi/1.7 bar

#3

Fixed Output

45MPHP22*

100 psi/6.9 bar

#7

22.0

83.3

0.92

3.47

1.96

57.85

66.6

2.78

46.25

45MP3

25 psi/1.7 bar

#3

Adjustable

45M4

25 psi/1.7 bar

#4

1.7 to 35.0

6.4 to 132.5

0.07 to 1.46

0.27 to 5.52

0.15 to 3.11

4.44 to 92.01

5.1 to 106.0

0.21 to 4.42

3.54 to 73.61

Fixed Output

45MP4

25 psi/1.7 bar

#4

35.0

132.5

1.46

5.52

3.11

92.01

106.0

4.42

73.61

Adjustable

45M5

25 psi/1.7 bar

#5

2.5 to 50.0

9.5 to 189.3

0.10 to 2.08

0.40 to 7.89

0.22 to 4.44

6.60 to 131.46

7.6 to 151.4

0.32 to 6.31

5.28 to 105.14

Fixed Output

45MP5

25 psi/1.7 bar

#5

50.0

189.3

2.08

7.89

4.44

131.43

151.4

6.31

105.14

Approx. Outputs @ 60 Hz

Approx. Outputs @ 50 Hz

NOTICE:

The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.

Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.

*pump supplied with injection check valve for 26-100 psi applications

The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates

10% increments of maximum output. (20:1 Turndown Ratio)

0.2 to 3.0

0.8 to 11.4

0.01 to 0.13

0.03 to 0.48

0.02 to 0.27

0.56 to 7.92

0.6 to 9.1

0.03 to 0.38

0.31 to 6.32

3.0

11.4

0.13

0.48

0.27

7.92

9.1

0.38

6.32

0.5 to 10.0

1.9 to 37.9

0.02 to 0.42

0.08 to 1.58

0.04 to 0.89

1.32 to 26.32

1.5 to 30.3

0.06 to 1.26

1.04 to 21.04

10.0

37.9

0.42

1.58

0.89

26.32

30.3

1.26

21.04

1.1 to 22.0

4.2 to 83.3

0.05 to 0.92

0.18 to 3.47

0.10 to 1.96

2.92 to 57.85

3.3 to 66.6

0.14 to 2.78

2.29 to 46.25

22.0

83.3

0.92

3.47

1.96

57.85

66.6

2.78

46.25

Advertising