4 function description, 1 introduction, 2 functions – Pilz PNOZ s50 C User Manual

Page 13: Section 4, Function description, Introduction, Functions, 4function description

Advertising
background image

Function description

Operating Manual PNOZ s50
1002194­EN­02

13

4

Function description

4.1

Introduction

The PWM relay PNOZ s50 is used for the safety­related shutdown of inductive loads.

It has two power outputs to activate two independent, inductive loads. Each power circuit is
switched independently by two inputs. Two feedback loops monitor the switch status of the
inductive loads. Two failsafe outputs signal the switch status of the inductive loads to the
higher level safety control system. A failsafe fault signal output signals any fault to a higher
level safety control system.

The device is configurable. All the parameters can be set via a rotary knob with pushbutton.
The state of the inputs and outputs, the configuration and any faults are shown on a dis­
play. The configuration is stored on a chip card.

There is an integrated counter, which records the number of operations for each power cir­
cuit.

Block diagram

A1

A2

Y20 Y21 Y22 Y23

Power

=

B1

B2

O1-

O1+

O2+ O2-

Feed-

back

Y10 Y11 Y12 Y13

Inputs

fast

O3 O4

O5

S35

Y1 Y2

Feed-

back

T0

T1

Inputs

fast

S36

Input

slow

Input

slow

Supply

S11

Logic

=

Fig.: Block diagram

Potential isolation, potential connection:

}

Potential isolation between the supply voltages A1/A2 and B1/B2.

}

Potential connection between the power outputs O1+/O1­, O2+/O2­ and the supply
voltage B1/B2.

}

Potential connection between the semiconductor inputs and single­pole outputs,
voltage output and supply voltage A1/A2.

4.2

Functions

4.2.1

Switching the power circuits on and off (fast shutdown)

The device has two safe dual­pole outputs O1+/O1­ (power circuit 1) and O2+/O2­(power
circuit 2), which can be switched using inputs Y10/Y11 (power circuit 1) and Y20/Y21
(power circuit 2):

Advertising