5 initial reset (initialize), Initial reset (initialize) -10, Initial reset (initialize) – KEYENCE IG Series User Manual
Page 46: T'5'v, Reference, Ig-e, Bas ic oper a tion s, Analog output scaling" (page 4-32), 9 key lock function" (page 3-21), Mode] button

3-10
IG-E
3
B
as
ic Oper
a
tion
s
3-5
Initial Reset (Initialize)
If the initial reset is performed, all of the setting items except for the calibration setting and
standard waveform registration are initialized. (When the sensor head setting is changed,
register the standard waveform again. "3-4
Registering the Standard Waveform (Gain
adjustment)" (page 3-9)
Also, with the same operation, the polarity of judgment output and edge check output, and
the analog output setting can be changed.
Main screen
1
While pressing the [MODE] button on the main screen,
press the [SET] button 5 times.
[
TGUGV] is displayed on the main display (upper level).
While pressing the
[MODE] button,
press the [SET]
button 5 times.
2
Press
S / T button to select [[GU] and press the
[MODE] button.
If [
PQ] is selected at this point, only the output polarity and analog
output settings can be changed without performing the initial reset.
[MODE] button
3
Press
S / T button to select the output polarity and
press the [MODE] button.
[MODE] button
4
Press
S / T button to select the analog output and
press the [MODE] button.
"10. Analog output scaling" (page 4-32)
[MODE] button
5
After the initialization is complete, [
GPF] blinks several
times on the sub display and the main screen is restored.
Note
While the calculation function is used, perform the initial reset for the main unit first.
Reference
• When buttons other than the
S / T button and [MODE] button are pressed during the
initial reset procedure, the initial reset is canceled and the screen in step 2 is restored.
• When you attempt to initialize the unit while the key lock function is
set, the screen shown on the right appears and the initialization fails.
Cancel the key lock before attempting to initialize the unit.
"3-9 Key Lock Function" (page 3-21)
LASER
BANK
0
1
2
3
HI
GO
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
HOLD
CALC
CHECK
;GU
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
T'5'V
GO
HOLD
CALC
CHECK
Performing the initial reset
PRP
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
QWV
GO
HOLD
CALC
CHECK
Output polarity
Setting value
Description
PRP
NPN output
RPR
PNP output
QHH
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
#P.)
GO
HOLD
CALC
CHECK
Analog output
Setting value
Description
QHH
Not output
W
Analog output after the judgment value is converted to the range from 0 to 5 V.
W
Analog output after the judgment value is converted to the range from -5 to 5 V.
W
Analog output after the judgment value is converted to the range from 1 to 5 V.
CORT
Analog output after the judgment value is converted to the range from 4 to 20 mA.
'PF
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
T'5'V
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
.QE
GO
HOLD
CALC
CHECK