RS-485 Master Unit (N-410) Settings

SETT

ING DEVICE OPER

A

T

IONS

4

Main Setting

The following describes the settings of the [Main setting] tab for the N-410.

Item

Description

Host mode

Select Multi-drop link mode, BL (SR) Multi-head mode or RF Multi-head mode
for Host mode.

Trigger setup

Set the trigger for when Multi-head mode is used.
When Interference suppression is enabled, set the timing ON time to 50 to 2550
ms.

Read mode

Select Single or Multi for Read mode.

Data-send timing

Select After read or At trigger-OFF for Data-send timing.
* This item is enabled only in the Single label mode.

Signal type

Select from Level and One-shot as the signal type.
* When One-shot is set, set the One-shot input time to 100 to 25500 ms.

State

Select Norm. open or Norm. close as the polarity of the input contact.

Input pulse width

Select 2ms or 10ms for the input time constant of the input contact.

Command for trigger ON

Set the Command for trigger ON using an ASCII text string or Hexadecimal.
The command is automatically converted to ASCII text string or Hexadecimal
before it is displayed.

Command for trigger OFF

Set the Command for trigger OFF using an ASCII text string or Hexadecimal.
The command is automatically converted to ASCII text string or Hexadecimal
before it is displayed.