The following describes the settings of the [Main setting] tab for the N-410.
Item
Description
Host mode
Select Multi-drop link mode, BL (SR) Multi-head mode or RF Multi-head mode
for Host mode.
Trigger setup
Set the trigger for when Multi-head mode is used.
When Interference suppression is enabled, set the timing ON time to 50 to 2550
ms.
Read mode
Select Single or Multi for Read mode.
Data-send timing
Select After read or At trigger-OFF for Data-send timing.
* This item is enabled only in the Single label mode.
Signal type
Select from Level and One-shot as the signal type.
* When One-shot is set, set the One-shot input time to 100 to 25500 ms.
State
Select Norm. open or Norm. close as the polarity of the input contact.
Input pulse width
Select 2ms or 10ms for the input time constant of the input contact.
Command for trigger ON
Set the Command for trigger ON using an ASCII text string or Hexadecimal.
The command is automatically converted to ASCII text string or Hexadecimal
before it is displayed.
Command for trigger OFF
Set the Command for trigger OFF using an ASCII text string or Hexadecimal.
The command is automatically converted to ASCII text string or Hexadecimal
before it is displayed.