I.C.E. HTDM Food Process Unit User Manual

Page 25

Advertising
background image

25

VII. Wiring



J1

24VAC Neutral

J2

24 VAC

J3

Normally open contact to purge
timer coil

J4

24VAC for purge timer common

J5

Normally open contact to supply
fan

J6

24VAC for supply fan common

J7

Solid State Relay (+ VDC)

J8

Solid State Relay (-VDC)

J9

Modulating gas valve control
signal (2-10 VDC)

10

Modulating gas valve ground (24VAC
common)

J11 Modulating gas valve feedback

signal (2-10 VDC)

J12 Heat mode/Standby (Switched 24VAC)

J13 Temperature sensor ground (-VDC)
J14 Temperature sensor supply (+5VDC)

J15 Temperature sensor signal (+VDC)

J16 Tachometer sensor signal (+VDC)

J17 Tachometer sensor supply (+5VDC)

J18 Tachometer sensor ground (-VDC)
1J9 Space Override contact

J20 System ground

J21 Space Override contact

J22 Flame detect in (24VAC)

J23 Remote Temperature Selector

Contact

J24 Remote Temperature Selector

Contact

J25 Building Management in

J26 Building Management in

Advertising