System Operation

50

Adept Cobra i600/i800 Robot User’s Guide, Rev G

Table 4-10. Contacts Provided by the XFP Connector

Pin

Pairs

Description

Requirements for
User-Supplied Front Panel

Voltage-Free Contacts Provided by Customer

1,9

Front Panel E-Stop CH 1 (N/C contacts)

User must supply N/C
contacts.

2,10

Front Panel E-Stop CH 2 (N/C contacts)

User must supply N/C
contacts.

3,11

Remote MANUAL/AUTOMATIC switch CH 1.
MANUAL = Open AUTOMATIC = Closed

Optional - jumper closed for
Auto Mode only operation.

4,12

Remote MANUAL/AUTOMATIC switch CH 2.
MANUAL = Open AUTOMATIC = Closed

Optional - jumper closed for
Auto-Mode-only operation.

6,14

Remote High Power On/Off momentary PB

User must supply momentary
push button to enable High
Power to system.

Nonvoltage-Free Contacts

5,13

a

a

Users must exercise caution to avoid inadvertently connecting 24 V signals to these pins,
because this will damage the electronics.

Adept Supplied 5 VDC and GND for High Power
On/Off Switch Lamp

User must supply lamp, or
use 1/4 W, 220 Ohm resistor.
System will not operate if not
present.

7,15

a

System 5 V power ON LED, 5 V, 20 mA

Optional - indicator only

8

No connection

See

Figure 4-9 on page 53

for a schematic diagram of the Adept Front Panel.