Maintenance

5

5.1

Field-replaceable Parts

The following two parts are the only field-replaceable parts:

These parts must only be replaced with the Adept Part Numbers identified in the
preceding table.

5.2

Periodic Maintenance Schedule

The following table gives a summary of the preventive maintenance procedures and
guidelines on frequency.

NOTE: The frequency of these procedures will depend on the particular
system, its operating environment, and amount of usage. Use the times in

Table 5-2

as guidelines and modify the schedule as needed.

NOTE: Special maintenance for the Cleanroom version of iCobra robots is
covered in

Section 8.5 on page 103

.

Table 5-1. Field-replaceable Parts

Part

Adept Part Number

Encoder battery

09977-000 (3.6 V, 6.8 Ah)
(This has replaced part number 02704-000)

AIB (Amp-In-Base)

04900-000

Table 5-2. Inspection and Maintenance

Item

Period

Reference

Check E-Stop, enable and key switches, and barrier
interlocks

6 months

See

Section 5.3

.

Check robot mounting bolt torque

6 months

See

Section 5.4

.

Check for signs of oil around harmonic drive.

3 months

See

Section 5.5

.

Lubricate Joint 3 (Z-axis) ball screw/spline

3 months

See

Section 5.6

.

Replace Encoder battery

5 to 10 years

See

Section 5.8