Figure 6-11. removing the cable strap plate – Adept i600 Cobra User Manual

Page 82

Advertising
background image

Optional Equipment Installation

82

Adept Cobra i600/i800 Robot User’s Guide, Rev G

Figure 6-10. Solenoid Placement Using Mounting Hardware

9. Install the appropriate lengths of 4 mm (5/32 in.) plastic tubing (supplied) into

the two output ports on the manifold. Route the tubing up along the tower
bracket next to the quill and down through the center of the quill. Use cable ties,
as needed, to secure the tubing.

10. Loosen the securing screw on the AIB chassis, and lower the chassis down flat.

See

Figure 5-2 on page 65

for the location of the securing screw.

11. Remove the cable strap plate by removing two screws and split washers. See

Figure 6-11

. This allows the harness to move when you lift the J1 cover in the next

step.

Figure 6-11. Removing the Cable Strap Plate

12. Remove the four screws for the Joint 1 cover and lift the cover up so you have

access to the tubing under the cover. See

Figure 6-12

.

Air intake
coupling with
spare air line

Tubing connected
to output port

Mounting screws for
solenoid assembly

Two M5 x 8 screws

Cable Strap Plate

Advertising
This manual is related to the following products: