05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

57

8302 Barcode

checksum

Status

Error while calculating the bar code check sum.

Action

Check transmitted data.

If the error continues to occur, contact Service. Send the transmitted Easy

Plug data.

8303

Bar code sample

Status

Error while calculating the bar code sample.

Action

Check whether the transmitted data is valid for the bar code type and

change the data.

8304

Bar c. plain-copy

Status

Error while integrating the plain-copy line in the bar code sample.

Action

Check whether the transmitted data is valid for the bar code type and

change the data.

8305

Bar code print

Status

Error while calculating the bar code print image.

Action

Press Online to acknowledge.

Action

Check whether the transmitted data is valid for the bar code type and

change the data.

8306 Plain-copy

len.

Status

Illegal: bar code plain-copy line has more than 300 characters.

Action

Reduce line length.

8307 Readline

dist.

Status

General software error.

Action

Turn off the printer, wait 30 seconds, then turn it back on.

See notes in “General software errors” section.

8308

Bar code ratio

Status

Illegal bar code ratio.

Action

Select another ratio.

8309 Module

range

Status

Maximum range of the bar code module exceeded.

Action

Reduce module range.