9013 head voltage, 9014 motor voltage, 9015 network init – Avery Dennison Monarch 9864 Error Messages User Manual

Page 65: 9016 dhcp failed, 9017 rtc read failed, Head voltage, Motor voltage, Network init, Dhcp failed, Rtc read failed

Advertising
background image

05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

65

9013 Head

voltage

Status

Faulty 5 V printhead supply voltage for one of the following reasons:

Only 9854: Printhead was connected to the wrong connector on the CPU

board.

Short circuit or the printhead is defective.

Action

Only 9854: Check if the printhead is connected to the correct connector on

the CPU board. Change the connector, if necessary.

Replace the printhead.

9014 Motor

voltage

Status

Faulty 45 V motor supply voltage. – a short circuit or the printhead is
defective.

Action

Replace the printhead.

9015

Network init.

Status

Error while the network initializes.

Action

Contact your network administrator.

9016 DHCP

Failed

Status

DHCP failed. This may happen, if parameter

INTERF. PARAM. >

ETHERNET PARAM. > IP Adressassign

is set to DHCP, but no IP address can be

found.

Action

Contact your network administrator.

9017

RTC read failed

Status

Error while trying to read the realtime clock (RTC). An Easy Plug command
to read out the RTC is sent, but no RTC is built in.

Action

Check if the printer is supplied with a RTC by printing a status printout.

See parameter

INFO PRINTOUT > Printer status

The actual date is on the printout below the header "Systemversion" if a
RTC is installed.

Check if the error occurs repeatedly or occasionally.

If it occurs repeatedly:

9854: replace the CPU board.

9864: Replace the RTC. If the error still occurs, replace the CPU board.

See notes in “General software errors” section if the error reoccurs.