Figure 21 – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 105

Advertising
background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

Successful continuity check during call set up

After a continuity check has succeeded during normal call set up, timer T24

(waiting for sending COT on receipt of backward check tone) should be

stopped and the transceiver removed. The application initiates the continuity

request thus indicating success and the call should be allowed to proceed in
the normal manner.

Figure 21. Example of a Continuity Check Success Outgoing Call Set Up

Call in Speech State:

Proceed as usual

ANM

ANM

COT (success)

COT (success)

ACM

ACM

IAM

IAM

ISUP

MODULE

USER

APPLICATION

NETWORK

105